AC EV charger safety inspections and RCD testing
Documented safety and condition checks for fleets, workplaces and commercial properties with existing AC EV chargepoints.
What we help you identify
- Damaged sockets, cables or tethered leads
- Signs of overheating, water ingress or deterioration
- Loose fixings, poor sealing or impact damage
- RCD/RCBO protection without recent test evidence
- Missing or unclear maintenance records
- Dirty or poorly presented chargepoints
“`
Many commercial EV chargers are installed, used, then forgotten
“`
A charger can continue delivering power while having a damaged socket, worn cable, loose mounting, compromised seal or unclear protective-device test history. A documented inspection gives your facilities, fleet or property team a clear record of charger condition and required actions.
Check safety and condition
We inspect the chargepoint, socket or tethered lead, enclosure, mounting, seals and visible signs of deterioration.
Test and document
Accessible associated RCD/RCBO protection is tested where safe, with results and limitations recorded.
Clean and report
Light external cleaning, photographs, observations and prioritised actions are included in the inspection.
“`
Who this service is for
“`
Designed for organisations that already operate AC EV chargepoints and need reliable evidence of their condition and maintenance requirements.
Fleets and depots
For businesses relying on AC chargers for vans, company cars and overnight fleet charging.
Offices and business parks
For workplace chargers used by employees, visitors or tenants where inspection history may be unclear.
Landlords and managing agents
For inherited, tenant-facing or shared chargers across commercial properties and managed developments.
“`
“`
Specialist advice without an installation sales agenda
ChargePointExpert focuses on the inspection and maintenance of existing AC charging infrastructure. We do not sell new charger installations.
Because we are independent of the original installer, our findings are based on the condition and test results of your existing equipment—not on creating an opportunity to replace it.
“`
What is included
“`
A focused inspection of existing commercial AC chargepoints, their physical condition and their accessible associated protection.
Inspection scope
- Charger make, model and asset identification
- External condition of the chargepoint
- Socket or tethered-cable condition
- Signs of impact damage, overheating or water ingress
- Mounting, fixings, seals and glands
- Accessible internal visual inspection where safe
- Protective-device and earthing observations
- RCD/RCBO testing where accessible and safe
- Basic functional charging test where possible
- RFID or access test where applicable
- Light external cleaning
- Photographic evidence and defect summary
- Suggested future inspection interval
Excluded unless agreed separately
- DC rapid or ultra-rapid chargers
- Emergency callouts
- Remote monitoring
- Manufacturer warranty work
- Guaranteed repair during the inspection
- Full EICR of the wider electrical installation
- Back-office or network support
- Testing of inaccessible protective devices
- Additional isolation or access arrangements
- Heavy cleaning, graffiti or hazardous contamination
No installation upsell: Your independent report can be passed to your existing electrician or preferred competent contractor.
“`
Clear fixed pricing
“`
Choose the inspection option that fits the number of accessible AC charging ports at your site.
Route Visit
1–4 AC ports
+ VAT
Dedicated Site Day
Up to 9 AC ports
+ VAT
£110 per port at full capacity
Two-Day Programme
Up to 18 AC ports
+ VAT
Larger Portfolio
19+ AC ports
Site-specific
*The £110 per-port price applies when nine accessible AC charging ports are completed during a £990 dedicated site day. Route Visit pricing is subject to geography, access and availability alongside other work in the area. Final scope may depend on charger type, safe access, isolation requirements and travel.
“`
What you receive
“`
A practical inspection report suitable for internal maintenance records, risk management and remedial planning.
Site summary
Number and type of chargers inspected, overall condition and principal observations.
Test and photo evidence
Relevant inspection photographs, accessible RCD/RCBO test results and recorded limitations.
Prioritised action list
Clear separation between safety concerns, maintenance defects and further investigation requirements.
“`
Frequently asked questions
“`
Is this only for AC chargers?
Yes. This service is focused on commercial AC chargepoints. DC rapid and ultra-rapid chargers are outside the current scope.
Is this the same as an EICR?
No. This is a focused inspection of the chargepoint and its accessible associated protection. It does not replace an EICR of the wider electrical installation.
Do you sell or install replacement chargers?
No. ChargePointExpert does not sell new charger installations. Your report can be provided to your existing electrician or preferred competent contractor.
Can every RCD or RCBO be tested?
Testing depends on safe access, the installation design, site permissions and the ability to interrupt the charging equipment. Any device that cannot be safely accessed or tested is recorded as a limitation.
How often should AC EV chargers be inspected?
There is no single interval suitable for every site. Frequency should reflect usage, environmental exposure, manufacturer guidance, previous defects and site risk. Your report includes a suggested future inspection interval.
Is cleaning included?
Light external cleaning is included. Heavy staining, graffiti removal, hazardous contamination and specialist cleaning are outside the standard scope.
“`
“`
Request an AC EV charger safety check
Send us your site postcode, number of charger units and AC charging ports, charger make and model if known, how the chargers are used and any known concerns.
Contact details
Email us directly or use the enquiry form.
Please include the site postcode, number of charger units, number of AC charging ports, charger make and model if known, how the chargers are used and whether the electrical distribution board is accessible.
Enquiry form
Complete the form below and we will confirm the appropriate inspection option.
“`